Recommended replacement:. Find a Reseller. Product Support. Product Overview Technical Specifications. Run time for load Min-max. Run time for load. Enter the total load power draw of all devices to be protected by the UPS here. Based on the value entered we will estimate the run time that you will have during a total power outage. Adding run time increases availability by allowing the system to operate through longer outages without shutting down.
Capacity Used. The maximum percentage of UPS capacity used to support your specified load. Output power capacity Uniquely designed to accept input power from any single phase, V power source such as a UPS, solar panel or other alternative energy power inputs. High availability architecture Different running modes : hot stand-by, integrated parallel, or centralized static switch for multi-modules leading to availability architectures.
Output synchronization to external source UPS systems can be synchronized with any other independent source for use with downstream static transfer switches.
Parallel capability Multiple units can be placed in parallel to meet power capacity and redundancy requirements. Intuitive monitoring Step by step navigation and menu screens for critical system information and data. Information is easy to access and presented in a very intuitive way.
The other Pulsar Ellipse devices can be used in either the vertical or the horizontal position. If installed vertically, Pulsar Ellipse must be positioned with the LEDs and buttons at the top to ensure stability fig 5.
Pulsar Ellipse Premium , other devices printer, scanner, etc. Filtered outlets are not powered in case of mains failure. The battery may be removed to comply with regulations and in view of correct disposal.
This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The system has its own power source the battery. Consequently, the power outlets may be energized even if the systems is disconnected from the AC power source. Dangerous voltage levels are present within the system. It should be opened exclusively by qualified service personnel. The battery supplied with the system contains small amounts of toxic materials. To avoid accidents, the directives listed below must be observed:.
The short-circuit current may be very high. Precautions must be taken for all handling: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles.
The UPS connection instructions and operation described in the manual must be followed in the indicated order. A protection circuit breaker must be installed upstream and be easily accessible. The system can be disconnected from the AC power source by opening this circuit breaker. Check that the indications on the rating plate correspond to your AC powered system and to the actual electrical consumption of all the equipment to be connected to the system.
If the system must be stored prior to installation, storage must be in a dry place. All handling operations will require at least two people unpacking, installation in rack system. This charges the battery, thus avoiding possible irreversible damage. During the replacement of the Battery Module, it is imperative to use the same type and number of element as the original Battery Module provided with the UPS to maintain an identical level of performance and safety.
Packing: UPS packing materials must be recycled in compliance with all applicable regulations. Lead is a dangerous substance for the environment if it is not properly recycled by specialized companies.
Pulsar MX RT offers a standard backup time of 5 minutes at full load. The Battery Integration System is intended for extended backup time configurations to conveniently stack and secure up to 5 modules on the same cart swivel wheels with brakes, leveling feet, seismic side panels, plates to lock modules, and screws included.
This extended battery cable will be used instead of the standard battery cable when battery modules are distant from each other located in two different enclosures, for instance.